12 - English
OPERATION
DRAINING THE TANK
See Figures 7 et 8, page 16.
To help prevent tank corrosion and keep moisture out of the air
used, the air tank of the compressor should be drained daily.
Turn the air compressor off, as shown in the shut down
section of the quick reference label.
Pull the ring on the safety valve to release until pressure
gauge reads less than 20 psi, as shown in the shut down
section of the quick reference label.
Release the ring.
Rotate drain valves counterclockwise to open, as shown
in the shut down section of the quick reference label.
Tilt tank to drain moisture from tank into a suitable
container.
NOTE: Condensate is a polluting material and should be
disposed of in compliance with local regulations.
If drain valve is clogged, release all air pressure, remove
and clean valve, then reinstall.
WARNING:
Unplug the air compressor and release all air from the
tank before servicing. Failure to depressurize tank before
attempting to remove valve can cause serious personal
injury.
Rotate drain valve clockwise until tightly closed.
CHECKING THE SAFETY VALVE
See Figure 8, page 16.
DANGER:
Do not attempt to tamper with the safety valve. Anything
loosened from this device could fly up and hit you. Failure
to heed this warning could result in death or serious
personal injury.
The safety valve will automatically release air if the air tank
pressure exceeds the preset maximum. The valve should be
checked before each day of use by pulling the ring by hand.
Turn the air compressor on and allow the tank to fill. The
compressor will shut off when the pressure reaches the
preset maximum.
Turn the air compressor off.
Pull the ring on the safety valve to release air for three to
five seconds to allow pressurized air to escape. Release
the ring. The safety release valve must reset and hold
pressure before all compressed air is exhausted from the
tank.
Any continued loss of air after performing the above steps
indicates a problem with the safety valve. Discontinue
use and seek service before continued use of the air
compressor.
WARNING:
If air leaks after the ring has been released or if the valve is
stuck and cannot be actuated by the ring, do not use the
air compressor until the safety valve has been replaced.
Use of the air compressor in this condition could result
in serious personal injury.