Ryobi OP400 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Chargeurs de batterie Ryobi OP400. Installation Guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 7
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
SPECIFICATION NO PEAC OP4026
PRODUCT EVALUATION AND ACCEPTANCE CRITERIA
WRITTEN
REISSUED
BY
APPROVED
SUPERSEDES
BY Stuart Miller
ISSUED:
PAGE 1 OF 7
NO. PEAC OP4026
ENG061.F
R01
T
T
e
e
c
c
h
h
t
t
r
r
o
o
n
n
i
i
c
c
I
I
n
n
d
d
u
u
s
s
t
t
r
r
i
i
e
e
s
s
N
N
o
o
r
r
t
t
h
h
A
A
m
m
e
e
r
r
i
i
c
c
a
a
,
,
I
I
n
n
c
c
.
.
General Information
Model Number: OP4026 (TTI #:130186006)
Description: Ryobi 40V 10S2P Lithium Ion Battery Pack
Test Procedure: New Product Qualification Procedure No. 105 Rev. 06
Nameplate Voltage: 40V
Scope: This PEAC is for the qualification of the OP4026 battery pack. It is intended to evaluate the product’s
compatibility with existing tools and chargers that are approved for use with this product. This revision serves to
test initial version of the product utilizing Samsung 13Q cells that was initially designed for European markets.
Thus, some references to 40V products may use 36V product test data as qualification data.
Compatible Chargers:
TTI Part #
Description:
140181001
UL version of EMEA Charger for 120V
Product Test Specifications:
I: Performance Testing
I.A: Battery Pack Discharge Test
Test to be conducted on each of (5) samples. Recharge battery packs using charger OP400.
1. Discharge samples at 1A. Plot discharge voltage, capacity (in Watt Hours), and pack temperature.
2. Repeat step 1 at 10A, and 20A for all (5) samples. Record same information from step 1.
3. Place each sample in 50°C chamber and allow temperature to stabilize. Connect pack to electronic
load outside of chamber (equipment at room temperature) and discharge pack at 20Amps. Record
same information from step 1, and conduct test on all (5) samples.
4. Repeat step 3 at 10°C, 0°C, and -10°C, for all (5) samples. Record same information from step 1.
5. Repeat step 3 at 1A for 0°C and -10°C for all (5) samples. Record same information from step 1.
Averaged measured voltages within 200ms after full discharge current has been applied must meet the
following minimum values.
Minimum Pack Voltage (V)
Discharge Temperature (ºC)
50ºC
22ºC
10ºC
0ºC
-10ºC
Discharge Rate
(A)
1A
41.0
40.5
40.1
10A
38.7
20A
38.4
37.5
35.5
33.5
32.6
Vue de la page 0
1 2 3 4 5 6 7

Résumé du contenu

Page 1 - OP4026

SPECIFICATION NO PEAC OP4026 PRODUCT EVALUATION AND ACCEPTANCE CRITERIA WRITTEN REISSUED BY APPROVED SUPERSEDES BY Stuart Mil

Page 2

SPECIFICATION NO. PEAC OP4026 PRODUCT EVALUATION AND ACCEPTANCE CRITERIA Page 2 of 7 R01 TTeecchhttrroonniicc IInndduussttrriieess NNoorrtt

Page 3

SPECIFICATION NO. PEAC OP4026 PRODUCT EVALUATION AND ACCEPTANCE CRITERIA Page 3 of 7 R01 TTeecchhttrroonniicc IInndduussttrriieess NNoorrtt

Page 4

SPECIFICATION NO. PEAC OP4026 PRODUCT EVALUATION AND ACCEPTANCE CRITERIA Page 4 of 7 R01 TTeecchhttrroonniicc IInndduussttrriieess NNoorrtt

Page 5

SPECIFICATION NO. PEAC OP4026 PRODUCT EVALUATION AND ACCEPTANCE CRITERIA Page 5 of 7 R01 TTeecchhttrroonniicc IInndduussttrriieess NNoorrtt

Page 6

SPECIFICATION NO. PEAC OP4026 PRODUCT EVALUATION AND ACCEPTANCE CRITERIA Page 6 of 7 R01 TTeecchhttrroonniicc IInndduussttrriieess NNoorrtt

Page 7

SPECIFICATION NO. PEAC OP4026 PRODUCT EVALUATION AND ACCEPTANCE CRITERIA Page 7 of 7 R01 TTeecchhttrroonniicc IInndduussttrriieess NNoorrtt

Commentaires sur ces manuels

Pas de commentaire