Ryobi DBJ50 Instructions d'exploitation Page 104

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 139
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 103
Page 95 Power Equipment Usage Manual (Rev. 5/10)
19.2. Setup & Use – Plunge Router
CAUTION: Before connecting router to power source, ALWAYS MAKE SURE
SWITCH IS IN THE “OFF” POSITION.
19.2.1. Selecting the Bit
Routers are furnished with 1/4" and 1/2" diameter collets that will accommodate bits with 1/4" or 1/2"
diameter shanks that are installed directly into the power unit collet.
19.2.2. Installing & Removing the Bit
CAUTION: DISCONNECT TOOL FROM POWER SOURCE.
a. Remove motor unit from base unit as follows:
Loosen clamp screw (A) Figure 1.
While holding base, turn motor unit
COUNTERCLOCKWISE until lower pin (B) in
motor housing is disengaged from groove in
base.
Lift motor unit free from base unit.
b. Clean and insert shank of bit into collet until shank bottoms. Then back it out approximately
3/8” to 1/2“.
c. Lay motor unit on its side on bench with the collet
pointing AWAY from you.
d. Place one wrench on flats on chuck with the opposite
end of the wrench resting on the bench to your left,
Figure 2.
e. Place other wrench on collet and tighten
COUNTERCLOCKWISE as shown in Figure 2. TIGHTEN
FIRMLY.
AVOID POSSIBLE DAMAGE TO COLLET. NEVER TIGHTEN COLLET WITHOUT BIT.
f. To remove the bit, reverse the foregoing procedure.
Vue de la page 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 138 139

Commentaires sur ces manuels

Pas de commentaire