Page 97 Power Equipment Usage Manual (Rev. 5/10)
19.2.5. Adjusting Sub-base Alignment
Applications using a template guide require the bit to be centered within the guide. This, in turn,
requires the center hole in the sub-base to be in line with the collet of the motor unit. Your model has
an adjustable sub-base which has been aligned at the factory. If the sub-base has been removed and/or
readjustment is required, proceed as follows:
CAUTION: Be sure power switch is in “OFF” position and tool is disconnected from power source to
avoid accidental starting of motor which could result in personal injury.
a. Loosen sub-base mounting screws just enough to allow sub-base to move on base.
b. Loosen clamp screw (see Figure 4), and adjust motor so that the collet nut engages the center
hole in the sub-base. Allow the sub-base to center itself on the collet nut. Tighten clamp screw.
c. Tighten sub-base mounting screws securely
19.2.6. Installing Motor in Plunge Base
CAUTION: DISCONNECT TOOL FROM POWER SOURCE.
a. Support clamp (see Figure 5) and loosen motor clamp screw approximately 1/2", with Allen
wrench (furnished).
b. Insert motor unit
into base with
switch positioned at
front of left handle
(see rear view in
Figure 6), and align
the four pins (A)
Figure 6, in the
motor case with the
slots (B) Figure 6, in the base.
c. Seat motor in base and tighten clamp screw to secure.
19.2.7. Removing Motor from Plunge Base
CAUTION: DISCONNECT TOOL FROM POWER SOURCE
a. Remove clamp screw, flat washer, lock washer, and
clamp locking nut.
b. Insert Allen wrench (A) Figure 7, as shown, to contact
locking plate. Tap lightly to release and remove locking plate.