12 — English
TROUBLESHOOTING
NOTE: FIGURES (ILLUSTRATIONS) START ON PAGE 14 AFTER
FRENCH AND SPANISH LANGUAGE SECTIONS.
PROBLEM POSSIBLE CAUSE SOLUTION
Air leak near the top of the tool or in the
trigger area
Loose screws
Worn or damaged O-rings or seals
Tighten screws
Install Overhaul Kit
Air leak near the bottom of the tool Worn or damaged O-rings or bumper Install Overhaul Kit
Tool does nothing or operates sluggishly Inadequate air supply
Worn or damaged O-rings or bumper
Verify adequate air supply
Install Overhaul Kit
Tool jams frequently Incorrect fasteners
Damaged fasteners
Loose magazine
Dirty magazine
Worn or damaged driver
Verify that fasteners are the correct size
Replace fasteners
Tighten screws
Clean magazine
Install Driver Maintenance Kit