Ryobi YG125CS Manuel d'utilisation et d'entretien Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
7 — English
DANGER:
Do not use oxygen, combustible gases, or bottled gases
as a power source for this tool. The tool will explode and
cause death or serious injury.
WARNING:
Do not allow familiarity with this product to make you
careless. Remember that a careless fraction of a second is
sufficient to inflict serious injury.
WARNING:
Always wear eye protection with side shields or goggles
marked to comply with ANSI Z87.1. Failure to do so could
result in fluids entering your eyes resulting in possible
serious injury.
WARNING:
Disconnect the tool from the air supply before leaving the
work area, moving the tool to another location, or handing
the tool to another person. Failure to do so could result
in serious personal injury.
APPLICATIONS
You may use this product for the purpose listed below:
Finish and Trim (Interior and exterior)
Floor Uderlayment
Cabinet Work
Casebacks
Furniture
Light Trim Moldings
Fascia and Soffits
Drawers
Staircases
Carpet installation
Mirror and Picture Frames
Crafts
Lattice
WARNING:
Always wear eye protection. Eye protection does not fit
all operators in the same way. Make sure the eye protec-
tion chosen has side shields or provides protection from
flying debris both from the front and sides.
OPERATION
PREPARING THE TOOL FOR USE
See Figure 1, page 13.
This is an oil-free tool, therefore lubrication is not required.
However, the occasional addition of air tool lubrication into
the air fitting on the tool will not adversely affect performance
or harm the tool.
Before connecting the tool, check the air compressor gauge
to be sure it is functioning within the proper range of 70-
120 psi.
NO-MAR NOSEPIECE
See Figure 2, page 13.
The no-mar nosepiece attached to the workpiece contact
of the tool helps prevent marring and denting when working
with softer woods.
WARNING:
Disconnect the tool from the air supply before removing
or replacing the no-mar nosepiece. Failure to do so could
result in serious personal injury.
The no-mar nosepiece can be removed by pulling it down
and away from the nose. To replace the no-mar nosepiece
fit it into place over the workpiece contact and push up at
the back to reseat.
When requesting a replacement nosepiece, request part
number 089041015059.
ADJUSTING THE EXHAUST
See Figure 3, page 13.
The adjustable exhaust on the end cap of the tool allows the
operator to direct the exhaust according to operator prefer-
ence. To adjust, turn the exhaust cap until the exhaust blows
in the desired direction.
WARNING:
Disconnect the tool from the air supply before leaving the
work area, moving the tool to another location, or handing
the tool to another person. Failure to do so could result
in serious personal injury.
Vue de la page 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 35 36

Commentaires sur ces manuels

Pas de commentaire